Guidelines for Stability Testing of Intranasal Products
1) Purpose
The purpose of this SOP is to provide a standardized procedure for conducting stability studies on intranasal products. Stability testing ensures that these products maintain their safety, efficacy, and quality under various storage conditions throughout their shelf life.
2) Scope
This SOP applies to all intranasal products produced or handled by the organization, including sprays, drops, and powders. It is intended for personnel involved in formulation development, quality control, and regulatory compliance.
3) Responsibilities
Formulation Scientist: Responsible for designing the stability study protocol and selecting appropriate stability-indicating parameters.
Quality Control (QC)
QA Team: Responsible for reviewing data, ensuring regulatory compliance, and approving the final stability report.
4) Procedure
4.1 Study Design:
- Identify stability-indicating parameters (e.g., potency, purity, spray pattern, and microbial limits) relevant to the intranasal product.
- Select appropriate analytical methods (e.g., HPLC, microbiological testing) to evaluate these parameters.
- Define storage conditions (e.g., room temperature, refrigerated) based on the product’s characteristics and regulatory guidelines.
- Develop a study protocol outlining the objectives, sampling schedule, and analytical methods to be used.
4.2 Sample Preparation:
- Prepare samples from representative production batches and label them with batch numbers, storage conditions, and sampling time points.
- Store samples in designated stability chambers under specified conditions.
4.3 Testing Schedule:
- Conduct initial testing on all samples to establish baseline data for the selected parameters.
- Perform follow-up testing at predetermined intervals (e.g., 1 month, 3 months, 6 months) to monitor changes in stability over time.
- Document all test results and analyze data for trends or deviations from acceptance criteria.
4.4 Data Analysis and Reporting:
- Analyze data using statistical methods to determine trends and compliance with acceptance criteria.
- Prepare a stability study report summarizing findings, conclusions, and recommendations for storage and handling conditions.
- Submit the report for QA review and archiving.
5) Abbreviations, if any
QC: Quality Control
QA: Quality Assurance
6) Documents, if any
Intranasal Product Stability Protocol: Document detailing the study plan and methodology.
Analytical Data Records: Data sheets for all tests performed.
7) Reference, if any
ICH Q1A(R2): Stability Testing of New Drug Substances and Products
8) SOP Version
Version 1.0